Skip to content
VerHill Associates

Represented line

Hitachi Energy

Hitachi Energy

High-voltage breakers, transformers, substations, grid automation and service.

Territory

Represented in Indiana, upstate New York, Ohio, Kentucky, western Pennsylvania and West Virginia. Public Power in Michigan (excluding the Upper Peninsula), Ohio and Indiana. Previously ABB Power Grids.

  • IN
  • OH
  • KY
  • MI*
  • NY*
  • PA*
  • WV

* MI Public Power; NY upstate; PA western

PGHV High Voltage

Manufacturer pages »

Circuit Breakers

  • Dead Tank SF6: 38kV up to 550kV
  • Live Tank: 72.5kV up to 1200kV
  • Disconnecting Breaker: 72.5kV up to 550kV

Hybrid Breakers

  • PASS 72.5kV up to 550kV: complete breaker with integral disconnector / earthing switches, voltage & current transformers

Gas Insulated Switchgear

  • GIS Breakers 72.5kV up to 1200kV

Generator Circuit Breakers

  • GCBs 50kA up to 300kA, up to 33,500A

Instrument Transformers

  • Current Transformers & Sensors: 25kV up to 800kV
  • Voltage Transformers: 25kV up to 800kV
  • Combined Current / Voltage Transformers: 72.5kV up to 420kV
  • Station Service Voltage Transformers: 46kV up to 550kV
  • Coupling Capacitor: 72kV up to 800kV

Surge Arresters

  • Distribution, Intermediate & Station Class
  • Polymer & Porcelain, AC & DC
  • Surge Counters

Capacitors & Filters

  • HV & MV Capacitor Units: AC & DC, single & three phase, wet & dry types, motor & transformer surge protection
  • Capacitor Banks: open rack & modular / metal enclosed
  • Harmonic Filters up to 550kV, >3 MVAR
  • LV Capacitor Units: 220V up to 1000V, up to 130 MVAR
  • Power Factor Controllers RCT & RVT, contactor or thyristor switched banks, power quality filters

Air Core Reactors

  • Shunt, Neutral Grounding, Harmonic Filter
  • Fault Current Limiting, Capacitor Inrush Limiting

PGTR Transformers

Manufacturer pages »

Distribution Transformers

  • Dry type: Open Wound, Cast Resin & Resibloc, Network, Transient Voltage Resistant, EcoDry
  • Oil type: Padmounted, Network / Submersible, Unit Substation, Substation. Up to 25MVA, up to 69kV

Power Transformers

  • Substation, Generator Step Up, Arc Furnace, Rectifier
  • Variable Speed Drives, Wind, Shunt & Series Reactor

Insulation & Components

  • Bushings, Composite Insulators, Tap Changers & Switches
  • Insulation Materials, Vacuum equipment, Oil treatment plants
  • Liquid level indicators, self-dehydrating breathers, liquid & winding temperature indicators
  • Pressure relief devices, Buchholz relays, dissolved gas analyzers

PGGI Grid Integration

FACTS

  • Fixed Series Compensation, Thyristor Controlled Series Compensation
  • STATCOM, Static Var Compensators
  • Synchronous Condenser Systems, Static Frequency Converters

Substations

  • Air Insulated, Gas Insulated, Hybrid Substations
  • Mobile Substations, Containerized & Pre-fabricated Substations
  • Digital Substations

Power Systems Consulting

  • Asset Evaluation & Systems Analysis
  • Commercial & Industrial System Studies
  • Equipment and Technology Selection, Design
  • Power Market and Economic Analysis, T&D System Studies

Substation Services

  • Installation & Commissioning
  • Extensions, Upgrades & Retrofits
  • Maintenance

PGGA Grid Automation

Manufacturer pages »

Enterprise Software

  • Digital Enterprise: single-source access to operations, assets, systems and the workforce
  • Asset & Workforce Management: fleet assets, linear assets and facilities

Network Control

  • Advanced Distribution Management Systems (ADMS)
  • Energy Management Systems (EMS), Generation Management
  • Market Management Systems, SCADA

Substation Automation Systems

  • Digital Substation, Station Level Solutions
  • Protection Solutions, Bay Control Solutions
  • Wide Area Monitoring

Substation Automation Products

  • Relion Relays, Combiflex Relays
  • Remote Terminal Units (RTUs)
  • Wireless Networks: broadband, point-to-point, mesh routers, mesh networks, radios, cellular gateways, network management

High Voltage Service

  • Installation, Commissioning, Radiography, Training, Spare Parts
  • Maintenance, Repairs, Extensions & Upgrades, End of Life Services
  • Condition monitoring, Partial discharge detection, Up-rate packages
  • Oil breaker replacement & parts, Remote monitoring
  • Interrupter replacement and repair, Mechanism replacement and repair

Transformer Repair & Engineering Services (TRES)

  • TXplore Inspection Robot, CoreTec Sensors
  • Transport & Haul, Installation, Commissioning, Supervision
  • Repairs (onsite & workshop), Asset Health, Inspection & Diagnostics
  • Life Cycle Assessments, Preventative Maintenance
  • Tap Changer Repair & Retrofits, Oil Processing, Dissolved Gas Analysis

Coverage detail

Where we cover this line

Our agreement is written to ZIP code, so these are the exact areas we can quote.

StateMarket ZIP codes
IndianaCommercial & Industrial46000–46299, 46500–47999
Public Power46000–47999
OhioCommercial & Industrial and Public Power43000–45999
KentuckyCommercial & Industrial40000–41899, 42000–42799
MichiganPublic Power48000–49799Excluding the Upper Peninsula.
New YorkCommercial & Industrial12000–12499, 12800–14999
PennsylvaniaCommercial & Industrial15000–16999
West VirginiaCommercial & Industrial24700–26899

Not sure whether your site falls inside the territory? Ask us and we'll confirm or point you to the right rep.